{"product_id":"cygnus-net8-artnet-node-lighting-network-data-management-copy","title":"Cygnus SPLIT8PRO DMX \/ RDM Interface Lighting Splitter Merger Art-Net","description":"\u003cul data-start=\"0\" data-end=\"831\"\u003e\n\u003cli data-section-id=\"1m3tb9d\" data-start=\"0\" data-end=\"80\"\u003e8-way DMX\/RDM splitter, booster and merger for professional lighting systems\u003c\/li\u003e\n\u003cli data-section-id=\"1pbmhbr\" data-start=\"81\" data-end=\"160\"\u003eDual A\/B DMX inputs with independent routing for flexible signal management\u003c\/li\u003e\n\u003cli data-section-id=\"fx3rv7\" data-start=\"161\" data-end=\"250\"\u003eElectronically opto-isolated outputs help prevent signal interference and data errors\u003c\/li\u003e\n\u003cli data-section-id=\"14q9qni\" data-start=\"251\" data-end=\"339\"\u003eSupports RDM (Remote Device Management) for remote fixture addressing and monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"7stqyh\" data-start=\"340\" data-end=\"405\"\u003e8 independent 5-pin XLR outputs with dedicated signal drivers\u003c\/li\u003e\n\u003cli data-section-id=\"7a426u\" data-start=\"406\" data-end=\"480\"\u003eToggle switches allow each output to select either A or B input source\u003c\/li\u003e\n\u003cli data-section-id=\"ir64ks\" data-start=\"481\" data-end=\"564\"\u003eConfigurable DMX refresh rates for compatibility with various lighting fixtures\u003c\/li\u003e\n\u003cli data-section-id=\"o5aw2w\" data-start=\"565\" data-end=\"632\"\u003eOLED display with rotary control for quick setup and monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"7ngq1x\" data-start=\"633\" data-end=\"691\"\u003eAudible DMX error alarm with A\/B status indicator LEDs\u003c\/li\u003e\n\u003cli data-section-id=\"1uedcbl\" data-start=\"692\" data-end=\"831\"\u003eRugged 1U 19-inch rackmount aluminium chassis with M10 rigging point for touring and installations \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"833\" data-end=\"1544\"\u003e\u003cstrong data-start=\"833\" data-end=\"874\"\u003eProduct Description (Under 100 Words)\u003c\/strong\u003e\u003cbr data-start=\"874\" data-end=\"877\"\u003eThe Elumen8 Cygnus SPLIT8PRO DMX\/RDM Interface is a professional-grade DMX distribution splitter, booster and merger designed for live events, theatres, touring productions and permanent lighting installations. It distributes DMX\/RDM data reliably across eight isolated outputs while reducing signal degradation and preventing data errors. Dual A\/B inputs with selectable routing provide flexible control options, while RDM support enables remote fixture configuration and monitoring. Housed in a durable 1U rackmount chassis, the SPLIT8PRO is ideal for complex lighting networks requiring stable and efficient signal management. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1546\" data-end=\"1576\"\u003e\u003cstrong data-start=\"1546\" data-end=\"1574\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1577\" data-end=\"2096\"\u003e\n\u003cli data-section-id=\"479xif\" data-start=\"1577\" data-end=\"1618\"\u003eInputs: 2 x Seetronic 5-pin XLR (A\/B)\u003c\/li\u003e\n\u003cli data-section-id=\"q4eayx\" data-start=\"1619\" data-end=\"1655\"\u003eOutputs: 8 x Seetronic 5-pin XLR\u003c\/li\u003e\n\u003cli data-section-id=\"1rppf0s\" data-start=\"1656\" data-end=\"1701\"\u003ePassthroughs: A\/B rear panel passthroughs\u003c\/li\u003e\n\u003cli data-section-id=\"16ft4up\" data-start=\"1702\" data-end=\"1736\"\u003eProtocol Support: DMX512 \u0026amp; RDM\u003c\/li\u003e\n\u003cli data-section-id=\"avuvz8\" data-start=\"1737\" data-end=\"1788\"\u003eIsolation: Outputs electronically opto-isolated\u003c\/li\u003e\n\u003cli data-section-id=\"19r9s5m\" data-start=\"1789\" data-end=\"1835\"\u003eDisplay: 1.8-inch OLED with rotary control\u003c\/li\u003e\n\u003cli data-section-id=\"ppurnh\" data-start=\"1836\" data-end=\"1866\"\u003eCooling: Convection cooled\u003c\/li\u003e\n\u003cli data-section-id=\"1a1pm75\" data-start=\"1867\" data-end=\"1905\"\u003ePower Supply: 100~240V AC, 50\/60Hz\u003c\/li\u003e\n\u003cli data-section-id=\"b1ewiv\" data-start=\"1906\" data-end=\"1931\"\u003ePower Consumption: 8W\u003c\/li\u003e\n\u003cli data-section-id=\"1xh925u\" data-start=\"1932\" data-end=\"1950\"\u003eFuse: T1A 250V\u003c\/li\u003e\n\u003cli data-section-id=\"pmysf\" data-start=\"1951\" data-end=\"1983\"\u003eDimensions: 44 x 483 x 155mm\u003c\/li\u003e\n\u003cli data-section-id=\"gdyib3\" data-start=\"1984\" data-end=\"2002\"\u003eWeight: 1.97kg\u003c\/li\u003e\n\u003cli data-section-id=\"j8gu00\" data-start=\"2003\" data-end=\"2096\"\u003eMounting: 1U 19-inch rackmount with M10 rigging point\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Elumen8","offers":[{"title":"Default Title","offer_id":64641975157085,"sku":"PROELUM252","price":325.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1062\/2766\/3197\/files\/ELUM252.png?v=1778231996","url":"https:\/\/ukdj.co.uk\/products\/cygnus-net8-artnet-node-lighting-network-data-management-copy","provider":"UK DJ","version":"1.0","type":"link"}